1. intro
This howto will highlight following issues regarding the SMA homestorage in combination with either the monophase SBSE and/or the STP-SE inverter(s).
-
the battery module with the highest serial number will become the master of the battery cluster.
-
if installing a brand new battery module on an existing old cluster, the master will try to push his old version to the old battery modules.
-
therefore, allways install first the new module, separartely and as the only one, even on a STP-SE.
-
on the SBSE you will need to upload the latest firmware file.
-
on the STP-SE everything will be done automaticaly, so be patient, this process can can take 20 minutes.
-
once double checked the firmware version, you add back the old battery modules back into the battery cluster.
2. latest downloads on 05aug2026
2.1. STP-SE
3. version check (samples)
3.1. SBSE
3.2. STP-SE